Micro Injection Grout

jahn product

* Concrete and hard stone - #31
* Brick and soft stone - #32

Jahn M30 contains no corrosive constituents, and achieves extraordinary flow capacity, penetration and strong adhesion. The M30 injection grout is offered in two formulations for varying substrates. To enhance penetration and bonding, a small amount of synthetic material is included. M30 can be applied via gravity feed or pressure injection into hairline cracks up to 3/16" (5.0 mm) in width. This product may be utilized in both non-structural simple void applications and structural load bearing situations, is available in two levels of compressive strength and can be customized through testing.

Features And Benefits

Single-Component: Easy to mix correctly, thereby improving quality control at the point of injection.

*Tenacious Adhesion: Strong bonding capabilities.
*Factory Controlled: No field chemistry resulting in product variation.
*Low Viscosity: Deep, thorough penetration.
*Simple Application: Can be applied by pouring or by pumping.
*Water Based: Environmentally and user safe. No solvent clean-up or disposal problems.

Application Procedures

Preparation
Wash the surface and interior of the crack using clean water to remove all dust, loose or deleterious material which could prevent proper flow and/or adhesion.

Mixing
The mixing ratio is approximately 5 parts powder to 2 parts water (or 3 parts powder to 1 part water) by volume. Mixing must be done with a high speed drill (3,000 RPM or higher) equipped with a Jiffler-type mixing paddle. After mixing, the grout should be poured into another clean container using a sieve. Additional or repeated agitation is necessary if the grout is allowed to sit prior to use.

Injection Procedures
Immediately before injection, moisten interior of the crack by flushing with water. If the crack is allowed to dry out before the grout is injected, this step must be repeated. This is very important.

 Transverse Cracks
M30 Transverse Cracks

Drill a series of injection ports in the center of the crack. These ports should be drilled in a downward direction. Seal the crack with removable, non-staining clay, sealant, or caulk.

Inject grout into the lowest port and continue until it flows freely from this port and other ports at the same level. Seal ports using non-staining clay, sealant, or caulk and proceed in identical fashion until the crack is filled. Clean up overflow and runs immediately with clean water.

Lateral Cracks (Delaminating Layers)
M30 Lateral Cracks

Drill a series of injection ports in a square configuration (90° angles) on the face of the substrate to create a "drill frame". Ports should be drilled in a downward direction. Wash the surface and interior of the crack using clean water to remove dust and loose. Any dust or debris remaining between the layers will impede the flow of the grout. If this is the case, more holes will be required to attempt to fill all hollow areas.

Inject grout into lower left port and proceed until it flows freely from this port and other ports at the same level. Seal ports using non-staining clay, sealant, or caulk. Inject grout into lower right port and proceed in identical fashion. The order of injection is lower left, lower right, upper left, then upper right. Clean up overflow and runs immediately with clean water.

Removal of Sealant
Let the grout dry (approximately 24 hours) and remove all sealant, caulk, or clay. After removing the sealant, repair the crack surface and injection holes with Jahn Mortar that matches the color and type of existing masonry.

Clean Up
While injecting, continually check for grout runs and spills on the surface of the masonry, and clean the surface before the grout has time to set. This is normally done with a clean sponge and water, and may have to be repeated several times, rinsing the sponge with clean water.

Remove uncured grout from tools and equipment with water as soon as possible. Cured grout many only be removed chemically or mechanically.

Safety Requirements
It is recommended that safety goggles, gloves, and a dust mask equipped with P-2 filters (or equivalent) be worn for protection while mixing the grout.

Limitations
* Do not apply Jahn Micro Injection Grout to a frozen or hot substrate. The applied grout must be protected from extreme heat, freezing, excessive wind, direct sunlight, and rain. Ambient temperature range should be 40° F to 90° F with low to average humidity.
* Do not add bonding agents to Jahn Micro Injection Grout or use them as surface preparation materials.

Packaging
A two gallon plastic pail contains approximately 15 lb. of material. Coverage will vary depending on the type of substrate and the size of the crack.

Storage And Shelf Life
Store material in a dry area away from direct sunlight. Ambient storage conditions should be in the range of 40° F to 90° F with low to average humidity. Average shelf life is six months in original, unopened packaging.

Technical Data
Jahn M30 - #31
Micro Injection Grout

Compressive strength 2 days approx.

3 days approx.

7 days approx.

28 days approx.
3600 psi


6400 psi


7400 psi


9000 psi
Tensile strength 28 days approx. 360 psi
Concrete granular size   Smaller than 6.3E-04 inches
Viscosity direct   80 cps
Specific gravity   1.77
Consumption   Ratio water/dry material: 45% of total weight
Application mixed product   Approx. 30 minutes (68 °F)

Jahn M30 - #32
Micro Injection Grout

Compressive strength 2 days approx.

3 days approx.

7 days approx.

28 days approx.
1264 psi


2243 psi


2591 psi


3160 psi
Tensile strength 28 days approx. 195 psi
Concrete granular size   Smaller than 6.3E-04 inches
Viscosity direct   80 cps
Specific gravity   1.77
Consumption   Ratio water/dry material: 45% of total weight
Application mixed product   Approx. 30 minutes (68 °F)

Warning
Not for internal consumption. Keep out of reach of children and animals.
07/2003

East Coast Distributors of Restoration Products & Supplies.

Don't spend money on the wrong product! Use the products the best contractors use. Our knowledge will help you get the job done right the first time!

Members of the National Association of Manufacturers Representatives

Many of these products have been featured on "This Old House"

Nu-Wal

Nu-Wal is a quick and efficient system for repairing damaged plaster substrates of walls and ceilings. more...

Silin Paints

Silin Paints mineral paints are made with liquid silicate, a mineral found in stone, brick, terra cotta, mortars and plaster. Unlike latex and acrylic paints, they form a molecular bond with the masonry substrate. more...

TerraCoat

TerraCoat Glazes have three different formulations designed to replicate the physical properties of the existing glaze. more...

Jahn Restoration Mortars

Jahn Restoration Mortars are used to repair and restore brick, bluestone, caststone, concrete, granite, limestone, marble, plaster, sandstone, slate and terra cotta. more...

R97 Water Repellent

Penetrating oil and water repellent. creates an easily cleanable surface for dirt, oil, grime, tar, soil. more...

Pro Shot®

Pro Shot® Floor Restorer & Finish will breathe new life to any floor with just one easy to apply application. more...

CSP Strippers

CPS Strippers for paint or epoxy removal from wood, concrete, metal, stone, and fiberglass. Products are water based, environmentally friendly, with no neutralization of the substrate required after use. more...

Waste Paint Hardner

Waste Paint Hardner quickly hardens latex and acrylic paints or stains and water based liquid products for easy disposal. more...

Paint Bridge

Paint Bridge is a non-woven synthetic spunbonded fabric. It has high tensile and tear strength in both directions. more...

D/2

D/2 Architectural Antimicrobial is a safe, easy to use liquid that removes a broad spectrum of biological deposits from hard environmental surfaces. more...

Roundtower Natural Hydraulic Limes

NHL limes are all natural and are the perfect product whenever traditional lime mortars are specified. more...